Send us a Message

We're always here for you, tell us how can we help?

Laser Machine Chiller Fault Diagnosis

The chiller cools the laser source and cutting head. Overheating will trigger alarms, reduce laser output stability and even damage the laser.

 

Common Symptoms

  • High temperature alarm pops up
  • Unstable water temperature fluctuation
  • Low water flow warning
  • Water leakage

 

Possible Causes

  • Dust clogging on condenser
  • Insufficient or contaminated circulating water
  • Water filter blocked
  • Cooling fan failure
  • Temperature parameter setting error
  • Pipeline air trapped inside

 

 

Solutions

  1. Clean the condenser regularly to remove dust.
  2. Use deionized water, replace circulating water on schedule.
  3. Clean or replace the blocked water filter.
  4. Check cooling fan operation, replace if broken.
  5. Reset temperature control parameters.
  6. Drain air inside the water circuit.

 

Reminder

Shut down the machine before any chiller maintenance. Do not run the laser if cooling alarm exists.